Sternal closure with sandwiched three-piece bioresorbable mesh

By A Mystery Man Writer

Background Median sternotomy is the most performed procedure in cardiac surgery; however, sternal displacement and bleeding remains a problem. This study aimed to investigate whether sternal reconstruction using a sandwiched three-piece bioresorbable mesh plate can prevent postoperative sternal displacement and bleeding more than a bioresorbable pin. Methods Patients (n = 218) who underwent median sternotomy were classified according to whether a sandwiched three-piece bioresorbable mesh plate and wire cerclage (group M, n = 109) or a bioresorbable pin and wire cerclage (group P, n = 109) were used during sternal reconstruction. The causes of postoperative sternal displacement and bleeding with computed tomography data were analyzed and compared between the groups. Results The preoperative patient characteristics did not significantly differ between the groups. However, the evaluation of sternal and substernal hematoma on postoperative day 5 using computed tomography showed sternal displacement in 4 (4%) and 22 (20%) patients, and substernal hematoma in 17 (16%) and 41 (38%) patients in groups M and P, respectively; this difference was significant. Furthermore, the amount of bleeding at 6 h postoperatively was lower in group M than in group P (235 ± 147 vs. 284 ± 175 mL, p = 0.0275). Chest reopening, intubation time, and length of intensive care unit and hospital stays did not differ between the groups. The evaluation of substernal hematoma based on computed tomography yielded a significantly lower for group M than for group P, revealing that the mesh plate was an independent predictor of substernal hematoma prevention. Conclusion Sternal fixation with a three-piece bioresorbable mesh plate could prevent postoperative sternal displacement, bleeding, and substernal hematoma more than sternal fixation with a pin.

ClearFix Rigid Sternal Fixation - Clearflow

MTMRecognition - Commonwealth of Virginia

BEYC #0293 - Bored Eye Yawn Club

Arthrex - FiberTape® Sternal Closure System

A new cable-tie based sternal closure system: description of the device, technique of implantation and first clinical evaluation, Journal of Cardiothoracic Surgery

Sternal closure by rigid plate fixation in off-pump coronary artery bypass grafting: a comparative study

10000 PDFs Review articles in STERNOTOMY

Sternal closure bone cerclage wiring - ZIPFIX™ - Depuy Synthes - metalic monofilament

Nonjacketing side-entry connectors and prosthetic disorder response systems Patent Grant Goldsmith May 25, 2 [Goldsmith; David S.]

Touring, Sport, & Mesh Jackets - Whitehorse Gear

©2016-2024, sincikhaber.net, Inc. or its affiliates